Mortara Instruments, Q40-1A, Stress System, Stress Testing
Click to enlarge
Sale Price: $17,322.00
Compared at: $17,798.00
You Save: $476.00
Product ID : MOR-Q40-1A
Manufacturer: Mortara Instrument
E-mail to a friend | Add To Wish List

Purchase

#AEHLM: Base System
#AFHLM: Mid Range System - Includes Q-Exchange (+$1,980.00)
#AFDM: Advanced System - Includes Q-Exhange & Advanced Software Options (+$2,970.00)
No Treadmill Specified
#01: Add Model TM55 Treadmill - 220 Volt (+$6,995.00)
#02: Add Model TM55 Treadmill - 110 Volt (+$6,995.00)

Overview

Quinton: Q-Stress System

Description

Cardiac Science: Item # Q40-1AEHLM  || The Quinton Q-Stress advanced cardiac stress test, treadmill system  to create the most comprehensive, reimbursable cardiac risk-profiling system in the industry and deliver accurate ECG tracings.  Includes complete workstation and printer.

 

 

Quinton Q-Stress

 

Cardiac Stress Test, Treadmill System The Quinton Q-Stress is the hospital industry's gold standard. Our cardiac stress test with treadmill system is the winner of multiple awards (most recently Frost & Sullivan's Market Engineering Award). Quinton Q-Stress is now in its ninth generation.

The Q-Stress cardiac stress test with treadmill system is designed with you in mind. Its easy-to-learn left-to-right workflow and simple-to-understand icons and intuitive controls guide technicians through the stress test. Busy stress labs use QuikLists to enter comments quickly and efficiently.

Our proprietary algorithm, baseline wander, and motion artifact filters reduce noise and produce clean ECG tracings even at high speeds and steep grades. Perfect for pharmacological stress tests as well. Patients will appreciate getting the best test results the first time.

And Q-Stress is HL7 and DICOM compatible! Q-Stress has the flexibility to connect to your Healthcare IT systems in the way that works best for you to enhance your clinical workflow. Click here for the DICOM Conformance Statement.

 

Features

 

  • Robust network connectivity – DICOM or HL7 connects with virtually everything needed for enhanced workflow. It's compatible with your echo system, nuclear camera, EMR, HIS, PACs and other healthcare IT systems.
  • Full disclosure reports; allows you to save the whole exam and review it at any time by exporting to your electronic medical record (EMR) system or hospital information system (HIS).
  • In-test review of stress testing data that includes "rewind" and "freeze frame" capabilities (both industry firsts) while still viewing the live test.
  • Ectopic capture and display for heartbeats outside the sinoatrial node.
  • Fully customizable panel display, plus the flexibility to add your own user-defined protocols.
  • Risk scoring, procedural re-analysis, and extensive report formatting options.
  • Warranty: 12-Month parts and labor (on-site).

 

Benefits 

 

  • Connectivity. Bi-directional communications using HL7 or DICOM enables the import of demographics, billing and procedures codes to Q-Stress. Export comprehensive test reports to help minimize documentation errors and lost billings.
  • Ease of use. The system’s Microsoft Windows compatibility (Vista or XP), left-to-right flow, and intuitive controls guide users through the procedure.
  • Accuracy. Tracings are accurate and clear, with clean waveforms even at high speeds and steep grades.
  • Instant replay. The Freeze Frame option allows you to "rewind" and view any section of any lead during the test.
  • Full disclosure. With the full disclosure option, you can save the entire cardiac stress test as a PDF and store it to your electronic records repository.
  • Easy analysis. Built-in analysis tools allow modifications for new patient data or for physiologic changes – resting cardiac data remains constant for comparison.
  • Customizable. You decide how you want your patient's cardiac test data presented. Create custom reports based on physician's preference. Easy reporting. QuikLists enable fast, efficient preparation of your reports

 

     

       

         

        OPERATING SYSTEM:

        Windows XP / Vista Ultimate / Windows 7 Ultimate

        POWER REQUIREMENTS:

        100/120 VAC 50/60 Hz 2.5 A nominal; 200/240 VAC 50/60 Hz 1.3 A nominal

        PROTOCOLS

        Standard:

        Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Ramped-low, Ramped-medium, Ramped high, Åstrand (ergometer), Persantine (pharmacological)

        Custom:

        Unlimited custom protocols can be created

        PATIENT MODULE:

        AHA 10-electrode with pinch or snap connectors AHA 10-electrode replaceable lead wires with pinch connectors IEC 10-electrode with pinch or snap connectors (available for International only) IEC 10-electrode replaceable lead wires with pinch connectors (available for International only)

        ECG

        Capability:

        True 12-lead

        Gain:

        5 mm/mV, 10 mm/mV, 20 mm/mV

        Lead Groups:

        Standard (Mason-Likar), Cabrera 12-lead, Frank, Canadian Bipolar

        Display:

        3, 6, 12 channels

        Performance Standard:

        AAMI-EC II: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance

        DISPLAY AND ANALYSIS FILTERS:

        Muscle artifact filter, baseline wander filter, 40 Hz low pass, line frequency. All filters can be turned on or of by the user

        ECG COMPUTATIONS

        Heart Rate:

        Computation 6 second average updated every 2 seconds

        ST Parameters:

        Level and slope

        Reference Point:

        J Junction (QRS offset), user-selectable

        QRS Detection:

        ASVV (Absolute Spatial Vector Velocity), user can select any three leads

        Beat Detection:

        Enhanced Quinton Stress algorithm for improved beat detection

        REPORTS

        In-Test:

        12-lead, average beat, 1-page write screen, continuous write screen, ectopic detail

        Final:

        Summary, tabular, worst case, average beats, in-test reports, trend graphs and peak exercise. Full Disclosure page addendum available with Full Disclosure option
        Reports can be viewed, printed, saved in PDF format, e-mailed or faxed. XML format for data export to other systems

        Custom:

        Unlimited custom report available

        OUTPUTS:

        TTL pulse for QRS detection (lead is user- selectable); 3 user-selectable analog outputs using any ECG lead

        EXTERNAL DEVICE INTERFACES

        Treadmills:

        TM 55/65, ST 55/65 (upgrade kit required)

        Ergometers:

        Corival, Ergoselect, Rehcor

        Blood Pressure Monitors:

        Colin BP412, Colin STBP-780 (Japan only), SunTech Tango+

        AVAILABLE PRINTERS

        Thermal:

        High-resolution with automatic feed and continuous printing capability

        Laser:

        Optional Laser printer: compact HP laser printer with high quality print

        Paper:

        8.5 in x 11 in (US letter) or 210mm x 300 mm (A4)

        NETWORK INTERFACE:

        Optional Microsoft compatible networking for file storage, distribution and email.

        EXPORT/COMMUNICATION
        PROTOCOL/FORMAT:

        XML, PDF , TCP/IP

        REMOTE TECHNICAL SERVICE INTERFACE:

        Remote service increases system uptime availability and decreases the user’s requirement to assist the troubleshooting process.
        Available via network or desktop connections (available only in the US)

        DISPLAY:

        483 mm (19 in) LCD lat panel

        ENVIRONMENTAL

        Operating conditions:

        Temperature: 50°F to 77°F (10°C to 25°C); Relative humidity: 20% to 80% non-condensing

        Storage conditions:

        Temperature: -14.8°F to 104°F (-26°C to 40°C); Relative humidity: 10% to 95% with condensation

        Thermal paper storage:

        at or below 77°F (25°C)

        Electrodes storage:

        at or below 86°F (30°C)

        SAFETY AND STANDARDS:

        EN 60601-1, Type CF defibrillation proof applied part
        IEC 61000-4-6
        IEC 61000-3-2
        IEC 61000-4-2
        IEC 61000-4-4
        IEC 61000-4-8
        IEC 61000-3-3
        IEC 61000-4-3
        IEC 61000-4-5
        IEC 61000-4-11
        RF emissions CISPR 11

        CART DIMENSIONS AND WEIGHT:

        30 in x 20 in x 36 in (762 mm x 508 mm x 914 mm); 120 lb (54 kg)

        WARRANTY:

        12 months parts and labor (on-site)

        OPTIONS:

        Networking, Q-Exchange, Full Disclosure, Freeze Frame, Re-Analysis

           

          CLICK HERE to View Brochure

           

          Products You May Like

          Philips ST80i Stress Test System
          $24,385.00