Mortara Instruments, V51, Burdick Vision Holter Software, Holter Monitors
Click to enlarge
Sale Price: $6,749.00
Compared at: $6,936.00
You Save: $187.00
Product ID : MOR-V51
Manufacturer: Mortara Instrument
E-mail to a friend | Add To Wish List

Purchase

#GI: Standard Edition
#GIJV: Add Heart Rate Variability Software & HL7 Communications (+$1,732.00)
#GIV: Add HL7 Communications only (+$743.00)
#GIJ: Add Heart Rate Variability Software only (+$991.00)
#1: No Recorders Included
#1D: Add One Model 4250 Recorder - available with only GI & GIJV software options above (+$1,650.00)
#1E: Add Two Model 4250 Recorders- available with only GI & GIJV software options above (+$3,071.00)
#1F: Add Five Model 4250 Recorders (+$6,366.00)

Overview

Burdick: Vision Premier Software

Description

Burdick: Item # V51-1GI  || The Burdick Vision Premier Holter system provides precise recognition of cardiac irregularities for advanced Holter analysis - Vision Premier Software with USB Download Cable (English Language)


Burdick Vision Premier Holter Software

 

For practices that need an advanced Holter monitoring solution, the Burdick Vision Premier Holter Analysis Software by Cardiac Science provides a powerful diagnostic tool. The Vision Premier software adds expanded ECG viewing choices and a more comprehensive list of diagnostic tools to the easy-to-use Vision software.

Like the more basic Vision software, Burdick Vision Premier provides top-quality cardiac data analysis. When tested against industry-standard MIT and AHA ECG databases, the Vision systems provided beat-detection results with 99.95 percent accuracy.

 

Features

 

  • Advanced capabilities, including automatic categorization of heartbeats, tachogram review, and full-disclosure viewing.
  • Automatic categorization of Holter information into unique morphology forms, including normal, ventricular, paced, SVE, unknown, and artifact.
  • System algorithms that automatically identify cardiac abnormalities and compile them into easy-to-read reports.
  • 7-second diagnostic strip labeling for each cardiac abnormality. Includes classification, time of occurrence, heart rate, and heartbeat annotations. Additional ECG-strip (EKG-strip) information can be inserted at any point.
  • On-screen displays for global or individual episode review or edit.
  • Automatic ST changes analyzes in three channels. Adjusts the analysis for different heart rates.
  • Software with a category-specific histogram to review the frequency and severity of an arrhythmia.
  • Tachogram review feature to identify, review, and note atrial fibrillation/flutter.
  • On-screen calipers for easy and precise measurements.
  • Can superimpose single- or multi-beat modes complemented with a 30-second full-disclosure review and RR interval plot.
  • Multiple ECG scanning modes (paging, superimposition, or retrospective review) for reviewing data, capturing arrhythmias, and compiling a final report.
  • Collect and analyze up to 48 hours of 3-channel ECG recordings.
  • Optional remote mode to download and review heart rate and ECG data anytime, anywhere.
  • Warranty: 13-Month parts and labor.

 

Benefits

 

  • Easy analysis. Automatically categorize Holter recordings into a comprehensive list of unique morphology forms.
  • Accuracy. Studies using AHA and MIT standardized databases prove Vision Premier software is 99.95% accurate.
  • Connectivity. Opt for industry-standard HL7 to enable communication between Vision Premier and various information systems including the suite of HeartCentrix data management solutions from Cardiac Science.
  • Flexibility. Advanced analysis tools like superimposition help isolate and identify cardiac arrhythmias.
  • Customization. Gives you the flexibility to easily customize your ECG reports and to set clinical limits according to your preferences and protocols.
  • Confidence. With more than fifty years developing tools for cardiac diagnosis, Cardiac Science has the experience required for dependable results.


CLICK HERE to View Brochure

 

COMPUTER REQUIREMENTS

Computer Requirements:

  • Intel 2.0 GHz or better
  • Memory:
    • 512 MB RAM or greater for Windows XP Professional (32-bit)
    • 1 GB RAM or greater for Windows 7 (32-bit)
    • 2 GB RAM or greater for Windows 7 (64-bit)
  • 80 GB hard drive or greater
  • Free Hard Drive Space Required for Program Installation:
    • 12 MB for the Vision Series application
    • 8 MB for electronic manuals (optional)
    • 250 MB for instructional AVIs (optional)
  • CDR or CDRW drive
    • ROXIO Direct CD version 5.0C up to 9.0 is required for allowing the user to back up and restore the Vision Series Software Patient Reports to a CDR or CDRW media for Windows XP Professional operating systems (not required for systems running Windows 7).
  • 17 in (432 mm) to 32 in (813 mm) SVGA monitor and display adapter supporting the following aspect ratios:
    • 4:3 (1024 x 768 resolution)
    • 5:4 (1280 x 1024) resolution
    • 16:10 (1280 x 800) resolution
    • 16:9 (1280 x 720) resolution and large fonts
  • 101-key enhanced and 104-key Windows keyboard
  • HP PCL-5 compatible printer (laser or inkjet), USB 2.0 recommended, print resolution of 600 dpi or better
  • Mouse
  • Windows XP Professional SP3 and Windows 7 Professional SP1
  • Fax/modem at 56K baud (optional)
  • Ethernet card at 10/100 Mbps minimum (optional)

For Digital Recorders:

  • One available USB port (version 2.0 recommended) for USB download and SD card

THIRD PARTY SOFTWARE
REQUIRED

ROXIO (Adaptec) Direct CD:

  • ROXIO Direct CD version 5.0C up to 9.0 is required in order to back up and restore the Vision Series Software patient reports to a CDR or CDRW media for Windows XP Professional operating systems. (Not required for systems running Windows 7.)

Adobe® Acrobat® Reader:

  • Version 6.0 or later. Allows viewing of manuals online

NOTES:

  • System performance on customer supplied computers is the responsibility of the customer
  • System security, access and privacy of patient data is the responsibility of the customer
  • If the computer is to be connected to a customer network, the customer must assign the IP network address
  • Anti-Virus scanning software should be installed and is the responsibility of the customer
  • Customer is responsible to provide hardware that meets the required country of origin regulatory standards

Products You May Like

Philips: HOLTER REMOTE SW
$2,032.00
Northeast | Holter & Event Monitor Combo
$1,100.00
Philips: HOLTER RECORDERS
$2,726.00
NorthEast | Software - Holter
$1,000.00
$750.00
Philips: HOLTER 1810 SOFTWARE
$9,725.00
NorthEast | Holter Monitor
$1,500.00
$1,295.00
Burdick: Digital Recorders
$1,831.00
$1,650.00
Burdick: Vision Software
$4,902.00
$4,769.00
Philips: HOLTER 2010 SOFTWARE
$19,887.00